1. Browse All Categories
  2. Emergency Communication Systems
  3. Bi-Directional Amplifiers
  4. Addressable Channelized Digital Class A and Class B Bi-Directional Amplifiers

Addressable Channelized Digital Class A and Class B Bi-Directional Amplifiers

NF-BDA400-1B, NF-BDA400-2B, NF-BDA150-1B, NF-BDA800-1B, NF-BDA700-1B, NF-BDA7800-2B

The NOTIFIER Addressable Channelized Digital Class A and Class B BDAs are Digital signal boosters for In-Building 2-way Emergency Radio Communication Enhancement with built-in NOTIFIER Fire Alarm Panel Addressable Monitor Module.

NOTIFIER Channelized Digital Class A and Class B BDAs are high gain, high power channel selective (Class A) or band-selective (Class B) signal boosters/bi- directional amplifiers that can be designed and customized to meet all public safety frequency band ranges in ERCES applications. It is intended to provide reliable two-way radio signal coverage inside buildings, tunnels and other structures. The state-of-the-art DSP-based filter design combined with our industry leading band-pass duplexer filters deliver a reliable performance in even the most challenging RF environments. The product delivers high RF power with 5W rated amplifiers while maintaining the industry leading power efficiency and reliability.

The state-of-the-art design delivers superior reliability and excellent performance in a small, lightweight, and economical package. The all inclusive design includes NFPA, IFC and UL® compliant supervisory interfaces, AC power supply, Battery Charger and Dedicated Annunciator Panel, NOTIFIER Channel and Band Selective, DSP Programmable Class A, Class B BDAs and power supplies.

The DSP Programmable Class A, Class B BDAs and power supplies are designed to meet and exceed the published UL2524 2nd Edition standard requirements (UL2524 2nd Edition listing pending) for In-building 2-Way Emergency Radio Communication Enhancement Systems,NFPA and IBC/IFC standards compliance-making it the best choice for public safety and other mission critical applications.

Features & Benefits:

  • Support for public safety frequency bands, various Channel selective (Class A) and Band Selective (Class B), DSP Programmable models available for UHF,800 MHz and 700/800 MHz Dual band
  • Lower total cost of ownership with High Power 5W (37dBm) Amplifiers with 10W (40dBm) Combined Downlink Power on 700/800 MHz Dual band models, 32-Channel Capacity (64 Channels with 700/800 MHz Dual band model) and ability to connect to NOTIFIER's SLC loop for monitoring of the BDA at the FACP
  • Excellent RF performance with high selectivity filter options and low processing delay filter options
  • High reliability with low noise figure, uplink noise squelch and oscillation suppression support
  • NFPA, IFC Code Compliance: NFPA compliant supervisory interfaces, NEMA-4 rated enclosures
  • High Efficiency Power Supply with a Choice of 12- 48Hr Battery Backup

Specifications

BDA Electrical Specifications

Specification NF-BDA400-D5-1A NF-BDA400-D5-1A NF-BDA800-D5-1A NF-BDA800-D5-1B NF-BDA7800-D5-2A NF-BDA7800-D5-2B
Frequency Range (Mhz) DL: 406.1-512
UL: 402-512
DL: 406.1-512
UL: 402-512
DL: 851-862
UL: 806-817
DL: 851-862
UL: 806-817
UL1: 799-805
UL2: 806-817
DL1: 769-775 DL2:
851-862
UL1: 799-805
UL2: 806-817
DL1: 769-775 DL2:
851-862
FCC ID 2AHPSB400M3A 2AHPSB400M3B 2AHPSB800M3A 2AHPSB800M3B 2AHVPSB7800M3A 2AHVPSB7800M3B
Amplifier Composite RF Output
Power dBm (W), Max.*1
DL: 37dBm (5W)
UL: 37dBm (5W)
DL: 37dBm (5W)
UL: 37dBm (5W)
DL: 37dBm (5W)
UL: 37dBm (5W)
DL: 37dBm (5W)
UL: 37dBm (5W)
DL: 40dBm (10W)
Combined
700+800MHz
UL: 37dBm (5W)
DL: 40dBm (10W)
Combined
700+800MHz
UL: 37dBm (5W)
Duplexer Insertion Loss dB
(typ.)
2.5–6 dB 2.5–6 dB <2.5dB <2.5dB <2.1dB <2.1dB
Gain and Power Ripple
within the rated Passband
dB (typ.)
<3dB
Selectable Channel Bandwidth
for Each Channel (kHz)
12.5, 25
12.5, 25, 150, 250,
500
12.5, 25
12.5, 25, 150, 250,
500
12.5, 25
12.5, 25, 150, 250,
500
Channel Filter Capacity
(Downlink + Uplink)
32 + 32 64 + 64
Selectable Channel Filter
Latency / Group Delay Per
Channel (μsec.)
12, 20, 48
Maximum System Gain (typ.)
dB
92
Gain Adjustment Attenuation
Range in 1dB Steps (dB)
0-35
Power Adjustment Range
1dB Steps(dB)
0-15
Intermodulation (IM3)
<-15dBm
Amplifier Noise Figure
<4dB
Maximum RF Power Input
for Rated IM3
-20dBm
Absolute Maximum Input
Power
0dBm
Impedance W
50
RF Connector Type N-Female
Supply Voltage VDC
28.5V DC
Power Consumption Under
Maximum Load
<90W
<150W

 

Warning: These devices are NOT CONSUMER devices. The devices are designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.

Note: Changes or modifications not expressly approved by the Manufacturer, responsible for compliance, could void the user’s authority to operate the equipment.


Mechanical and Environmental Specifications

Specification NF-BDA400-D5-1A NF-BDA400-D5-1A NF-BDA800-D5-1A NF-BDA800-D5-1B NF-BDA7800-D5-2A NF-BDA7800-D5-2B
Enclosure Environmental Rating NEMA-4 (Type-4)
Dimensions
(WxDxH)
23.23” x 8.32” x 24” 23.23” x 8.32” x 25.4”
Weight
(With Duplexers)
Typ. (lbs)
<59
Enclosure Color Red (RAL3000)
Operating Temperature °F (°C) -22 to +140 (-30 to +60)
Recommended
Operating
Environment
Temperature
°F (°C)
-14 to +86
(-10 to +30)

Codes and Listings:

  • NFPA 72 Compliance
  • NFPA 1221 Compliance
  • IFC Compliance
  • FCC Title 47 Part 90
  • FCC Title 47 Part 15b

Resources

Basket Size :
0 MB out of 50 MB

Document Name Asset Type Type & Size Modified Date
Brochures pdf | 1.50 MB 06/29/2020
Data Sheets pdf | 0.27 MB 10/12/2020
References pdf | 0.12 MB 12/10/2019

Media & Visuals

NOTIFIER BDA

NOTIFIER BDA Video