DS Dialer for NOTIFIER ONYX, INSPIRE

HON-DACT-DS
The Honeywell® solution for connecting a NOTIFIER Onyx, INSPIRE fire alarm system to central station via the public switched telephone network.

The DS Dialer provides dual telephone line communication between a standalone FACP or network of FACPs to a central receiving station to report system status. The DS Dialer mounts in a red enclosure external to a fire panel It uses modular jacks to interface the primary and secondary phone lines to the public switched telephone network. The DS Dialer consists of a main circuit board and telephone (POTS) card enclosed in a red box.

Features & Benefits:

  • Collects system data from the connected FACP and sends it to the central receiving station
  • Serves as a fire alarm communicator to the central station
  • Provides dual telephone lines (primary and backup) to ensure communication
  • Provides dual telephone line voltage detection
  • Employs Ademco® Contact ID protocols
  • Recognizes dial tones (350 and 440 hertz typical in most networks)
  • Automatically dials programmed central station phone numbers
  • Automatic line seizure takes control and disconnects any local premises phones on the same line
  • Generate Central Station reports using CLSS Site Manager
  • LED status indicators for Lost Panel Connection, and Central Station Handshake Signal, and Communication Failure
  • Communicates vital system status

Specifications

COMPATIBLE PANELS:

NOTIFIER INSPIRE PANELS: N16E, N16X
NOTIFIER ONYX PANELS: NFS-320, NFS-640, NFS2-640, NFS-3030, NFS2-3030

COMPATIBLE RECEIVERS:

  • Ademco™ 685 (with 685-8 Line card with Rev. 4.4d software)
  • Ademco MX8000 (with 124060V206B and 124063 Line Card Rev. B)
  • Silent Knight® 9500 (with version V2.4 receiver and 126047 Line Card Rev. G)
  • Silent Knight 9800 (with 124077V2.00 receiver and 126047 Line Card Rev. M)
  • Honeywell® FBI CP220FB (with software version 3.9)
  • Osborne Hoffman 2000E® (with receiver software version 7301)
  • Radionics 6600 (with 01.01.03 receiver software and 01.01.03 line card)
  • SurGard MLR2 (with software version 1.86)
  • SurGard System III (with software 1.72)
  • SurGard MLR-2000 (with DSP4016 and version 1.6 Line Card)

COMMUNICATION FORMATS:

  • Ademco Contact ID

POWER:

  • Operating Voltage Range: 18 VDC - 30 VDC
  • Typical Current Consumption: 200mA @ 18V, 150mA @ 24V

ENVIRONMENT:

  • Operating Temperature: 32°F - 120°F (0°C - 49°C)
  • Storage Temperature: 14°F - 140°F (-10°C - +60°C)
  • Relative Humidity: 1% - 93% Noncondensing

PHYSICAL:

  • Dimensions: 10 in (height) x 2 3/4 in (width) x 8 in (length)
  • Weight: 2 lbs

AGENCY LISTINGS & APPROVALS:

The listings and approvals below apply to the HON-DACT-DS. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Contact Honeywell for the latest listings.

  • ETL: Control Number - 5025335, Conforms to UL STD 864

STANDARDS & CODES

  • FCC ID: DS Dialer - 1W6AL02ACGWMB
  • National Fire Protection Association:
    • NFPA 70
    • NFPA 72

Resources

Basket Size :
0 MB out of 50 MB

Document Name Asset Type Type & Size Modified Date
Data Sheets pdf | 0.17 MB 08/01/2024